4.9 Removing air from the fuel circuit
If air enters the fuel system, it must be removed before the engine can be started.
Air can enter the system if:
The fuel tank has been run dry or drained.
One of the low pressure fuel pipes leaks during operation or has been disconnected.
The fuel filters have been replaced.
WARNING:
Diesel fuel under pressure can penetrate the skin or eyes and cause serious personal
injury, blindness or death.
WARNING:
Do not open high-pressure pipe
connectors on the fuel system when
the engine is running. Wait at least 30
sec. after the engine has stopped. If
the jet of high-pressure fuel comes
into contact with your skin, the fuel
will penetrate the skin causing severe
injuries. Get medical help
immediately!
IMPORTANT:
In case of fuel filter changing, a bleeding
procedure is needed. Refer to the relevant
procedure.
GUID-D1B25E8D-8B03-40ED-9500-659C60C74C87-low.png [Low]
Fig. 60
GUID-42F7FC0A-FDAC-431A-9514-ABBB043642FD [V3]
4. Maintenance
F Series 175
39940211 (555124)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Valtra F Series and is the answer not in the manual?

Valtra F Series Specifications

General IconGeneral
BrandValtra
ModelF Series
CategoryTractor
LanguageEnglish

Related product manuals