4 Parts Replacement RJ-901C/RJ-900C  Maintenance Manual
4-54
NOTE
When removing the cleaner head, note the following.
• Do not touch the cleaner head with your bare hands.
• Make sure that the cleaner head get no dust or oil.
• Install the cleaner head so that the point of the cleaner head is located to the observer's right side.
• Insert the cleaner head into the holder to the full depth securely.
4.7.4 Replacing Flushing Box Assembly
1. Remove the screw retaining the flushing box assembly to the platen base (tapping screw M3 × 6, S tight
cup: 2pcs).
2. Replace the flushing box assembly
3. To reassemble the unit, reverse the removal procedure.
No. Part name
1 Cleaner head
2
Head point
No. Part name
1 Flushing box assembly
2
Flushing box assembly screw
1
2
1
2