3 Specifications RJ-901C/RJ-900C  Maintenance Manual
3-10
3.5 Choosing a Place for the Plotter
WARNING
• Do not place the plotter in a location under the following conditions. Doing so may cause
the product to fall, become damaged, or cause injury.
• Unstable surfaces
• Slanted areas
• Locations that are subject to vibration from other product
• Do not stand on the plotter or place any heavy objects on it.
Doing so may cause it to fall over, become damaged, or cause injury.
• Do not cover the ventilation hole of the plotter with cloth, such as a blanket or table cloth.
Doing so could prevent the plotter from ventilating and cause fire.
• Keep the plotter away from humid and dusty areas. Failure to do so may result in electrical
shock or fire.
(1) Installation Environment Requirements
Choose a place for plotter installation following the requirements of the table below.
Table 3-1 Installation Environment Requirements List
Installation space 5m
2
or more, 2.6m or more is required for the width
Floor loading capability 2940Pa (300kgf/m
2
) or over
Electrical
specifications
Voltage AC 100 V - 120 V ± 10% or AC 200 V - 240 V ± 10% (auto-switching)
Frequency 50/60Hz ± 1Hz
Capacity 10A or more
Environmental conditions Temperature Humidity
Operation
environment
10º C (50F) to 35ºC (95F) 20% to 80%, with no condensation
Plotting accuracy
warranty range
15ºC (59F) to 28ºC (82.4F) 20% to 60%, with no condensation
Rate of change 2ºC/hour or less 5%/hour or less