12
DS2
-
21P5
Terminal
Function
Exp
lanation
Suppress current high
harmonics, to connect
DC reactor
1 and 2 is short when out of factory.
Connect DC reactor between 1 and
2 to suppress current high harmonics.
L
,
N
Power input of main
circuit
Single-phase AC 200240V, 50/60Hz
Ground
Connect to the ground terminal of motor,
to be grounded
U
,
V
,
W
Motor connection
Connect to the motor
Ground
Connect to the ground terminal of power,
to be grounded
P+
,
PB
Regenerative braking
resistor connection
Connec
t regenerative braking resistor
between P+ and PB
DS2
-
2□P□
-
A
,
DS2
-
21P5
-
B
Terminal
Function
Explanation
P+
,
PB
Regenerative braking
resistor connection
Connect regenerative braking resistor
between P+ and PB
L1
,
L2
,
L3
Power input of main
circuit
3-phase AC 200240V, 50/60Hz
PE
Ground
Connect to the ground terminal of
power, to be grounded
U
,
V
,
W
Motor connection
Connect to the motor
3-1-2Typical Wiring Example
1
L
N
U
V
W
P+
PB
2
1
2
L2
U
V
W
P+
PB
L1
L3
FIL
N
L
CN2
M
PG
U
V
W
P+
PB
Braking
resistor
Servo drive
1MCCB
1
MCCB
: breaker for inverter
FIL
: noise filter
1
2

Table of Contents

Other manuals for Xinje DS2 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS2 series and is the answer not in the manual?

Xinje DS2 series Specifications

General IconGeneral
BrandXinje
ModelDS2 series
CategoryServo Drives
LanguageEnglish

Related product manuals