5-4-6. Skip current signal (/ZCLAMP)
When /ZCLAMP signal is triggered in internal position mode, cancel the current stage
running, enter the next stage as different conditions of change step mode.
/Z
-
CLAMP
signal
Change step mode
E
x
ecution
0
Cancel current stage, execute the next stage at once
1
C
ancel current stage, execute the next stage when the
change step signal is ON
2
Cancel current stage, execute the next stage at once
Input signal setting:
5-4-7. Reference origin
(1) Find the reference origin
To find out the physical origin of working table and make it as the coordinates origin of
point position control. Users can select finding reference origin at forward or reverse side.
Function setting:
P2
-
94
n.xxâ–¡x
Unit
Default
Range
Suitable mode
Modify
Effect
-
0
0~1
5
,
6
Servo
OFF
Re
-
power on
Note: P2
-
94=0, find reference origin function is invalid.
P2
-
94=1, this function is valid.
Signal setting:
Related parameter setting:
P2
-
94
The quantity pass
the Z phase signal after leaving the limit switch
Unit Default
Range
Suitable
mode
Modify Effective
Number
2
1~
F
5
, 6
Servo
OFF
Immediately
P2
-
95
The speed hitting the proximity switch
Unit Default
Range
Suitable
mode
Modify Effective
0.1rpm 600 0~50000 5, 6 Servo OFF Immediately
P2
-
96
The speed leaving the proximity switch
Unit Default
Range
Suitable
mode
Modify Effective
0.1rpm 100 0~50000 5, 6 Servo OFF Immediately
Parameter
Signal
Type
Default
Meaning
Suitable
mode
Modify
Effect
P5
-
21
/Z
-
CLAMP
Input
n.000
0
Need to
distribute
3
,
4
,
7
Any
Re
-
power
on
1.
/Z
-
CLAMP
can be distributed to input terminal by P5
-
21. Refer to chapter 5
-
12
-
1.
2./Z-CLAMP is zero clamp function in speed mode.
Parameter
Signal
Type
Default
Meaning
Suitable
mode
Modify
Effective
P5
-
18
/SPD
-
A
Input
n.0000
Need
to
distribute
3
,
5
,
6
Any
Re
-
power
on
P5
-
19
/SPD
-
B
Input
n.0000
Need
to
distribute
3
,
5
,
6
Any
Re
-
power
on
1.
/SPD
-
A
,
/SPD
-
B
can be distributed to the input terminal via parameter
P5
-
18
,
P5
-
19
, refer to chapter
5-12-1.
2. In position mode, /SPD-A can trigger the forward side to find the reference origin, /SPD-B can
trigger the reverse side to find the reference origin.
3. In internal speed mode (mode 3), /SPD-A and /SPD-B auto-switch to internal speed selection signal.

Table of Contents

Other manuals for Xinje DS2 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS2 series and is the answer not in the manual?

Xinje DS2 series Specifications

General IconGeneral
BrandXinje
ModelDS2 series
CategoryServo Drives
LanguageEnglish

Related product manuals