56
5-6-1. Control mode selection
5-6-2. Internal speed setting
P3
-
01
Internal speed
1
Unit
Default
Range
Suitable mode
Modify
Effective
1rpm
100
-
5000
~
+5000
3
Any
Immediately
P3
-
02
Internal speed
2
Unit
Default
Range
Suitable mode
Modify
Effective
1rpm
200
-
5000
~
+5000
3
Any
Immediately
P3
-
03
Internal speed
3
Unit
Default
Range
Suitable mode
Modify
Effective
1rpm
200
-
5000
~
+5000
3
Any
Immediately
5-6-3. Input signal setting
Switch the running speed by below input signal:
(1) Function realization
Parameter
Set value
Meaning
Modify
Effective
P0
-
01
3
Speed contr
ol: internal speed selection
Servo
OFF
Immediately
Function:
internal speed selection will set 3 motor speeds and select the speed by external signal.
It is
not need to configure external speed generator or pulse generator.
Parameter
Signal
Type
Defa
ult
Meaning
Suitable
mode
Modify
Effective
P5
-
17
/SPD
-
D
Input
n.0000
Need to distribute
3
,
5
,
6
Any
Re
-
power on
P5
-
18
/SPD
-
A
Input
n.0000
Need to distribute
3
,
5
,
6
Any
Re
-
power on
P5
-
19
/SPD
-
B
Input
n.0000
Need to distribute
3
,
5
,
6
Any
Re
-
power
on
1.
/SPD
-
D
,
/SPD
-
A
,
/SPD
-
B
can be distributed to input signal by parameter
P5
-
17
,
P5
-
18
,
P5
-
19
. Refer
to chapter 5-12-1.
2. When the running mode is 5, 6, /SPD-D auto-switch to origin setting; /SPD-A auto-switch to
forward finding reference origin; /SPD-B auto-switch to reverse finding reference origin.
Input signal
Direction
Running speed
/SPD
-
D
SPD
-
A
SPD
-
B
0
0
0
Forward
Internal
speed is zero
0
1
P3
-
01
:
SPEED1
1
1
P3
-
02
:
SPEED2
1
0
P3
-
03
:
SPEED3
1
0
0
Reverse
I
nternal speed is zero
0
1
P3
-
01
:
SPEED1
1
1
P3
-
02
:
SPEED2
M
Servo motor
Run the motor
at set speed
Servo unit
Speed selection
SPEED1 P3-01
SPEED2 P3-02
SPEED3 P3-03
User parameter
/SPD-D
/SPD-A
/SPD-B
Input
No need external
speed or
pulse generator

Table of Contents

Other manuals for Xinje DS2 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS2 series and is the answer not in the manual?

Xinje DS2 series Specifications

General IconGeneral
BrandXinje
ModelDS2 series
CategoryServo Drives
LanguageEnglish

Related product manuals