31
5. Repower on the servo drive to make this function effective.
4-4-4Check Alarm Information
Set group No. to 2 in auxiliary function mode and enter checking alarm information mode.
The following steps show how to check alarm information.
1. Press STATUS/ESC key to select Auxiliary Function mode.
2. Press INC or DEC key to set group No. to 3, and press ENTER key.
3. Press INC, DEC or ENTER key to modify the alarm No.
4. Press and hold ENTER key to display corresponding alarm information.
Member No.
Description
Unit
F3
-
00
Current alarm code
1
F3
-
01
Current warn code
2
F3
-
02
Alarm/warn code 1 when alarm
F3
-
03
U
phase current when alarm
A
F3
-
04
V phase current when alarm
A
F3
-
05
DC b
us
-
voltage when alarm
V
F3
-
06
IGBT
module
temperature when alarm
F3
-
07
Speed when alarm
rpm
F3-08 Internal torque command when alarm
F3
-
09
V
-
REF
value
when alarm
V
F3
-
10
T
-
REF
value
when alarm
V
F3
-
11
Alarm/warn code 2 when alarm
F3
-
12
Alarm/warn code 3 when alarm
F3
-
13
Alarm/warn code 4 when alarm
F3
-
14
Alarm/warn code 5 when alar
m
F3
-
15
Alarm/warn code 6 when alarm
F3
-
16
Alarm/warn code 7 when alarm
1: F3-00=0 indicates that there is no alarm.
2: F3-01=0 indicates that there is no warn.
4-4-5Reset Parameters to Default
The following steps show how to reset parameters to default.
1. Press STATUS/ESC key to select Auxiliary Function.
2. Press INC or DEC key to set group No. to 4, and press ENTER key.
3. Press and hold ENTER key, and the panel displays “0” and is blinking.
4. Set the value to 1. Press and hold ENTER key to confirm.
5. Repower on the drive and the parameters are all reset to default.
4-4-6. External monitoring
Select F5-00 in auxiliary function, the panel displays “C-OUT” which means external
monitoring mode, COM1 is effective, operate panel is ineffective. At this time user can
debug the servo via PC.
Press STATUS/ESC to return.
4-5Parameter Setting
Select or adjust the functions via parameter setting. Please refer to appendix 1 for
parameters list.
The following steps show how to change a parameter.
Check the permitted range of the parameters in appendix 1.

Table of Contents

Other manuals for Xinje DS2 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS2 series and is the answer not in the manual?

Xinje DS2 series Specifications

General IconGeneral
BrandXinje
ModelDS2 series
CategoryServo Drives
LanguageEnglish

Related product manuals