80
E-014
Encoder ABZ
wire break
Encoder wiring error,
encoder broken,
encoder is not
connected
Check the wiring of encoder, and
re-connect the encoder after
power-off, or replace the damaged
encoder
E-015
Speed changes too
fast (encoder
feedback error)
The encoder wiring is
error, or the encoder
has interference
Check the wiring of encoder, or
add shield layer for the encoder
wire
E-016 Overload
Run overload for long
time
Reduce the overload running time,
change a motor with larger rated
power
E-017
Power off when
running
Bus voltage is too low
when running
Re-power on after the bus voltage
is normal
E-018
Erase parameter
error
Voltage is too low
when power on,cannot
erase the parameter
Check the power supply and
re-power on
E-031 Motor code error
Motor code cannot
match to drive type
Set the motor code in F2-00 again
E-032 Initialization error
System chip is
damaged
Contact Xinje or an authorized
distributor

Table of Contents

Other manuals for Xinje DS2 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS2 series and is the answer not in the manual?

Xinje DS2 series Specifications

General IconGeneral
BrandXinje
ModelDS2 series
CategoryServo Drives
LanguageEnglish

Related product manuals