26 | XIO USER MANUAL | 2106424MNAB
2.3.4 Customer data collection files
The data collection files contain all the trend data the XIO generates. These data files are in the tfData
directory with the running configuration files. The type and amount of collection data depend on the
number and type of trends active on the device.
IMPORTANT NOTE
: The tfData directory also contains the calibration files if the controller has
been
field-calibrated.
2.4 User interface
The PCCU32 software running in a Windows
®
environment is the main user interface to the XIO. PCCU32
supports several view levels and can be configured to provide role-based secure access to the controller
for the following tasks:
Initial configuration and commissioning (setup)
Monitor the controller operation and performance
Add, configure, and optimize applications (configuration)
Calibration
Data collection
2.5 Secure service access interface
The Secure Shell (SSH) and Secure File Transfer Protocol (SFTP) on the XIO allow secure login access and
file transfer capability for advanced service access. SSH provides an encrypted communication channel,
which requires private key authentication for access to the controller. Secure access is available for
troubleshooting purposes only and is reserved for advanced users and ABB technical support or
development personnel.
3 Installation
This chapter provides information for XIO installation and setup.
IMPORTANT NOTE
: Read the installation chapter and review user drawings before beginning
installation.
Make sure to review safety warnings carefully.
WARNING
Bodily injury. Although there may be alternate methods of installation and
commissioning of the
XIO, ABB recommends that technicians perform the procedures in the order
presented: plan, install, wire, then apply power, verify power
-on sequence, and configure.
3.1 Site planning and requirements
XIO installation requires that customer-supplied enclosures, power sources, wiring, and location comply
with the specifications described in this section.
WARNING
Bodily injury. Carefully review the specifications in this section to select compliant
equipment. Failure
to comply with these specifications may create unsafe conditions, resulting in
bodily injury and equipment damage.
3.1.1 Enclosure requirements
Install an XIO standalone on a DIN rail on an interior wall, in an XCORE enclosure, or in a customer-
supplied enclosure.
!
!