ELECTRIC SYSTEM
6 -28
Pegaso 650 I.E.
 #(%#+).'4(%%.').%/),02%3352%
3%.3/2
To check operation of sensor:
â—† Slip off the rubber protection (1).
â—† Disconnect the electric terminal from the sensor (2).
◆ With a tester (scale x 100 Ω) check for breaks between
the tongued terminal (3) and the casing of the sensor.
Correct value with engine off: 0 Ω
Correct value with engine running:
∞ Ω
If the values do not correspond to those indicated, check
that the engine oil level is correct, and change the sensor,
if necessary.
Release 00/2002-02
- 00