3.19 PLU Connection
3.19.1 Referenced PLU Function
If you press REFERENCE key after calling up a PLU which has reference
information, reference will be shown on the display.
To use this function, you have to set reference department and reference
PLU when you create PLU.
3.19.2 Coupled PLU Function
Automatically coupled PLU is called up after transaction.
You can use this function when you sell two or more items as package.
To use this function, you have to set reference department and reference
PLU when you create PLU.
3.20 Sales Operation Control Parameters
3.20.1 Fixed Weight
- You can set fixed weight when you create PLU
If you call up this PLU, the weight is not changed.
- You can use IN WEIGHT key.
Call up a PLU and enter a fixed weight by using OVERRIDE key and
press IN WEIGHT key.
3.20.2 Prepack Without Report
The transaction data is not added to report while using prepack mode.
- You have to set Parameter 597(Prepack report) to use this function. Also,
Parameter 596 should be set to Y