Network commissioning and diagnostics Group Table API
XBee/XBee-PR S2C ZigBe RF Module
118
View group
The purpose of the View Group command is to get the name string which is associated with a
particular endpoint and groupID.
The following example gets the name string associated with the endpoint E7 and groupID 1234.
The packet:
Preamble = 11 01 +LocalDevice64Addr+”FFFE E6 E7 0006 C105 00 00"
The packet is addressed to the local node, using a source endpoint of 0xE6, clusterID of 0x0006, and
profileID of 0xC105. The destination endpoint E7 is the endpoint parameter for the View Group”
command.
ZCL_header = 01 ee 01"
The first field is a frame control field which specifies a Cluster Specific command (0x01) using a Client-
>Server direction(0x00). The second field is a transaction sequence number which is used to associate
the response with the command request. The third field is the command identifier View Group
(0x01)
1
.
ZCL_payload = “3412”
The two byte value is the groupID in little-endian representation.
The packet in raw hex byte form:
7e001911010013a2004047b55cfffee6e70006c105000001ee013412d4
The response in raw hex byte form, consisting of two packets:
7e001d910013a2004047b55cfffee7e68006c1050009ee01003412044142434424
7e00078b01fffe00000076
The command response in decoded form:
ZigBee Explicit Rx Indicator
API 0x91 64DestAddr 0x0013A2004047B55C 16DestAddr 0xFFFE SrcEP 0xE7 DestEP 0xE6
ClusterID 0x8006 ProfileID 0xC105 Options 0x00
RF_Data 0x09EE010034120441424344
The response in terms of Preamble, ZCL Header, and ZCL payload:
Preamble = 910013a2004047b55cfffee7e68006c10500”
The packet has its endpoint values reversed from the request, and the clusterID is 0x8006 indicating a
Group cluster response.
ZCL_header = 09 ee 01"
The first field is a frame control field which specifies a Cluster Specific command (0x01) using a Server-
>Client direction (0x08). The second field is a transaction sequence number which associates the
response with the command request. The third field is the command identifier View Group (0x01)
2
.
ZCL_payload = “00 3412 0441424344"
1
ZigBee Cluster Library, document 075123r02:View Group Command, section 3.6.2.3.2.
2
ZigBee Cluster Library, document 075123r02:View Group Response, section 3.6.2.4.2.

Table of Contents

Other manuals for Digi XBee

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee and is the answer not in the manual?

Digi XBee Specifications

General IconGeneral
BrandDigi
ModelXBee
CategoryControl Unit
LanguageEnglish

Related product manuals