AT commands Diagnostic commands
XBee/XBee-PRO® S2C ZigBee® RF Module
250
Default
0
TP (Temperature)
The current module temperature in degrees Celsius. The accuracy is ± 7 degrees. 1 °C = 0x0001 and -1
°C = 0xFFFF.
Note This command is only available on the XBee-PRO device.
Parameter range
0x0 - 0xFFFF
Default
N/A
Diagnostic commands
The following commands are diagnostic commands.
VR (Firmware Version)
Reads the firmware version on a device as a 4-digit hex number.
Parameter range
0 - 0xFFFF [read-only]
Default
Set in the factory
VL (Version Long)
Shows detailed version information, device type, time stamp for the build, Ember stack version, and
bootloader version.
Parameter range
N/A
Default
N/A
HV (Hardware Version)
Display the hardware version number of the device.
Read the device's hardware version. Use this command to distinguish between different hardware
platforms. The upper byte returns a value that is unique to each device type. The lower byte indicates
the hardware revision.
Note The XBee returns a value of 0x22xx for this command. The XBee-PRO returns a value of 0x21xx.