AT commands I/O settings commands
XBee/XBee-PRO® S2C ZigBee® RF Module
243
Parameter range
0, 1, 6
Parameter Description
0 Unmonitored digital input
1 SPI data available indicator
6
Packet trace interface data output. Must be set along with D1 = 6 to output traces for
OTA sniffing.
Default
1
D0 (AD0/DIO0 Configuration)
Sets or reads the function of AD0/DIO0.
Parameter range
0 - 5
Parameter Description
0 Unmonitored digital input
1 Commissioning Pushbutton
2 Analog input, single ended
3 Digital input
4 Digital output, low
5 Digital output, high
Default
1
D1 (AD1/DIO1/PTI_En Configuration)
Set or read the function for the AD1/DIO1/PTI_En configuration.
Parameter range
0 - 6
Parameter Description
0 Unmonitored digital input
1
SPI_ATTN - Analog input, single ended for the through-hole device