AT commands Addressing commands
XBee/XBee-PRO® S2C ZigBee® RF Module
221
Addressing commands
The following AT commands are addressing commands.
DH (Destination Address High)
Set or read the upper 32 bits of the 64-bit destination address. When you combine DH with DL, it
defines the 64-bit destination address that the device uses for data transmission.
Special definitions for DH and DL include 0x000000000000FFFF (broadcast) and 0x0000000000000000
(coordinator).
Parameter range
0 - 0xFFFFFFFF
Default
0
DL (Destination Address Low)
Set or read the upper 32 bits of the 64-bit destination address. When you combine DH with DL, it
defines the 64-bit destination address that the device uses for data transmission.
Special definitions for DH and DL include 0x000000000000FFFF (broadcast) and 0x0000000000000000
(coordinator).
Parameter range
0 - 0xFFFFFFFF
Default
0xFFFF (Coordinator)
0 (Router/End Device)
MY (16-bit Network Address)
Reads the 16-bit network address of the device. A value of 0xFFFE means the device has not joined a
ZigBee network.
Parameter range
0 - 0xFFFF [read-only]
Default
0 - 0xFFFE
MP (16-bit Parent Network Address)
Parameter range
0 - 0xFFFE [read-only]
Default
0xFFFE