AT commands Security commands
XBee/XBee-PRO® S2C ZigBee® RF Module
231
Parameter range
0 - 1
Default
0
AR (Aggregate Routing Notification)
Set or read the periodic time for broadcasting aggregate route messages. If used, these messages
enable many-to-one routing to the broadcasting device. Set AR to 0x00 to send only one broadcast, to
0xFF to disable broadcasts, or to other values for periodic broadcasts in 10 second units.
Parameter range
0 - 0xFF (x10 sec)
Default
0xFF (disabled)
Security commands
The following AT commands are security commands.
EE (Encryption Enable)
Set or read the encryption enable setting.
Parameter range
0 - 1
Parameter Description
0 Disabled
1 Enabled
Default
0
EO (Encryption Options)
Configure options for encryption when EE = 1. Set unused option bits to 0. Options include:
Options Description
0x01 (ZigBee) Send the network key in the clear (unencrypted) over- the-air during a join
0x02 (Smart Energy) Enable as a trust center (Coordinator only)
0x08 (Smart Energy) Authenticate during joining (End Device and Router only)