AT commands Sleep commands
XBee/XBee-PR S2C ZigBe RF Module
252
CT (Command Mode Timeout)
Sets or reads the Command mode timeout parameter. If a device does not receive any valid
commands within this time period, it returns to Idle mode from Command mode.
Parameter range
2 - 0x1770 (x 100 ms)
Default
0x64 (10 seconds)
CN (Exit Command mode)
Immediately exits Command Mode and applies pending changes.
Parameter range
N/A
Default
N/A
GT (Guard Times)
Set the required period of silence before and after the command sequence characters of the
Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering
Command mode.
Parameter range
0x1 - 0x0CE4 (x 1 ms) (max of 3.3 decimal sec)
Default
0x3E8 (one second)
CC (Command Character)
Sets or reads the ASCII character value the device uses between Guard Times of the Command mode
sequence (GT + CC + GT). The Command mode sequence enters the device into Command mode.
For more information about Command mode sequence, see Command mode options.
Parameter range
0 - 0xFF
Default
0x2B (the ASCII plus character:+)
Sleep commands
The following AT commands are sleep commands.

Table of Contents

Other manuals for Digi XBee

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee and is the answer not in the manual?

Digi XBee Specifications

General IconGeneral
BrandDigi
ModelXBee
CategoryControl Unit
LanguageEnglish

Related product manuals