110 MES1000, MES2000 Ethernet Switches
gigabitethernet 1/0/3
Local client
------------
Administrative configurations:
Mode: active
Unidirection: not supported
Link monitor: supported
Remote loopback: supported
MIB retrieval: not supported
Mtu size: 1500
Operational status:
Port status: operational
Loopback status: no loopback
PDU revision: 3
Remote client
-------------
MAC address: a8:f9:4b:0c:00:03
Vendor(oui): a8 f9 4b
Administrative configurations:
PDU revision: 3
Mode: active
Unidirection: not supported
Link monitor: supported
Remote loopback: supported
MIB retrieval: not supported
Mtu size: 1500
console#
5.16.11 CFM protocol configuration
Ethernet CFM (Connectivity Fault Management), IEEE 802.1 ag enables monitoring, search and
troubleshooting in Ethernet networks; allows to control the connection, isolate the faulty network
segments and to identify the clients falling under networks restrictions.
Protocol uses the following terms:
Maintenance Domain (MD): a network segment which belongs to and managed by a single
operator.
Maintenance Association (MA): a collection of endpoints (MEP) with the same MAID
(Maintenance Association Identifier), which defines the type of service.
Maintenance association End Point (MEP): service endpoint located at its threshold.
Maintenance domain Intermediate Point (MIP): intermediate point for a domain.
Global configuration mode commands
Command line request in global configuration mode appears as follows:
console(config)#
Table 5.106 Global configuration mode commands
Command
Value/Default value
Action
ethernet cfm domain name
[level level]
name: (1..32) characters
level: (0..7)/0
Create (or change level) of CFM domain (MD) with the 'name'
name and enter the domain configuration mode.
- levelCFM domain level
no ethernet cfm domain
name
Remove CFM domain (MD) with the 'name' name.
Domain configuration mode commands
Command line request in domain configuration mode appears as follows: