158 MES1000, MES2000 Ethernet Switches
Port Result Length [meters] Date
----------- --------------- ---------------- --------------------------
gi1/0/1 Not tested
gi1/0/2 Not tested
gi1/0/3 Not tested
gi1/0/4 Not tested
gi1/0/5 Not tested
gi1/0/6 Not tested
gi1/0/18 Not tested
gi1/0/19 Not tested
gi1/0/20 Not tested
gi1/0/21 Not tested
gi1/0/22 Not tested
gi1/0/23 Not tested
gi1/0/24 OK -- 24-Mar-2014 11:52:31
te1/0/1 Fiber
te1/0/2 Fiber
te1/0/3 Fiber
te1/0/4 Fiber
5.23.2 Optical transceiver diagnostics
Command line request in global configuration mode appears as follows:
console(config)#
Table 5.179 Global configuration mode commands
Command
Value/Default value
Action
optical-transceiver
threshold notify-interval
interval
interval: 30-3600
seconds/600 seconds
Set the time period until the repeated warning/alarm message
generation via the syslog/snmp protocol.
no optical-transceiver
threshold notify-interval
Set the default value.
Ethernet interface configuration mode commands
Command line request in Ethernet interface configuration mode appears as follows:
console# configure
console(config)# interface {fastethernet fa_port| gigabitethernet gi_port}
console(config-if)#
Table 5.180 Ethernet interface configuration mode commands
Command
Value/Default value
Action
optical-transceiver threshold
action { parameter | all } {
none | syslog | snmp-trap }
parameter: (current, input-
power, output-power,
temperature, voltage)
Assigned action (do not perform any actions, generate syslog
message, generate snmp trap), that should be executed, when
values cross the thresholds for the selected parameter:
- current
- input-power
- output-power
- temperature
- voltage
optical-transceiver threshold
values parameter high-alarm
high-warning low-warning
low-alarm
parameter: (current, input-
power, output-power,
temperature, voltage)
Values for:
current: (0-131000) uA
input-power: (-40000-
8200) mdBm
Specify the threshold values, which, when crossed, will cause
syslog/snmp-trap message generation for the specific
parameter.
- current
- input-power
- output-power
- temperature