server_uptime
475
The server Commands
server_uptime
Displays the length of time that a specified Data Mover has been
running since the last reboot.
SYNOPSIS
server_uptime { <movername> | ALL }
DESCRIPTION server_uptime displays the length of time that the specified Data
Mover has been running since its last reboot.
The ALL option executes the command for all of the Data Movers.
OPTIONS No arguments
Displays the length of time that a Data Mover has been up.
EXAMPLE #1 To display how long a Data Mover has been up, type:
$ server_uptime server_2
server_2 : up 28 days 0 hours 15 min 41 secs
EXAMPLE #2 To display how long all the Data Movers have been up, type:
$ server_uptime ALL
server_2 : up 28 days 0 hours 15 min 41 secs
server_3 : up 2 days 5 hours 11 min 31 secs