S600 Instruction Manual
1
14
2
15
3
16
4
17
5
18
6
19
4
1
21
24
5
2
22
25
6
3
23
26
13
14
15
16
17
18
19
19
18
17
16
15
14
13
12
11
10
9
8
7
24
5
+15V
+15V
+15V
+15V
0-1 V
+12V
1mA
0-1 V
+12V
1mA
0-1 V
+12V
1mA
SKT A
SKT B
SKT C
COMMON + VE
DIG IN 5-
DIG IN 8-
COMMON + VE
DIG IN 9-
DIG IN 10-
DIG IN 11-
DIG IN 12-
COMMON + VE
DIG IN 13-
DIG IN 14-
DIG IN 15-
DIG IN 16-
COMMON + VE
RAW PULSE +
OUTPUT -
8
21
9
22
10
20
11
24
12
25
13
23
8
7
20
30
31
32
33
35
34
12
9
27
10
28
11
29
36
37
37
36
35
34
33
32
31
30
29
28
27
26
25
4
23
3
22
2
21
1
20
HITHIT
4 - 20 mA
1 - 5 V
1 - 5 V
SKT A
SKT B
SKT C
ADC 1+
ADC 2+
ADC 3+
ADC 4+
ADC 5+
GND
ADC 6+
ADC 7+
ADC 8+
ADC 9+
ADC 10+
GND
ADC 11+
ADC 12+
GND
PULSE OUT 1+
PULSE OUT 2+
PULSE OUT 3+
PULSE OUT 4+
PULSE 1-4 COM
+ DENSITY
-INPUT 1
+ DENSITY
-INPUT 2
+ DENSITY
-INPUT 3
+ PULSE
-OUTPUT 5
DIG OUT 1+
DIG OUT 2+
DIG OUT 3+
DIG OUT 4+
COMMON GND
DIG OUT 5+
DIG OUT 6+
DIG OUT 7+
DIG OUT 8+
COMMON GND
DIG OUT 9+
DIG OUT 10+
DIG OUT 11+
DIG OUT 12+
COMMON GND
+ DUAL PULSE
- CHANNEL 1
+ DUAL PULSE
- CHANNEL 2
+ DUAL PULSE
- CHANNEL 3
+ DUAL PULSE
- CHANNEL 4
SUPPLY
DAC 4 OUTPUT
GROUND
SUPPLY
DAC 3 OUTPUT
GROUND
SUPPLY
DAC 1 OUTPUT
GROUND
SUPPLY
DAC 2 OUTPUT
GROUND
I+
PRT 1 V+
INPUT V-
I-
I+
PRT 2 V+
INPUT V-
I-
I+
PRT 3 V+
INPUT V-
I-
DIG IN 1-
DIG IN 2-
DIG IN 3-
DIG IN 4-
DIG IN 6-
DIG IN 7-
SERVICE
SERVICE
SERVICE
SERVICE
SERVICE
SERVICE
0v
0v
0v
+24v
+24v
+24v
+24v
P144 IIO 1
LK 29
LK 30
LK3
3
10K
LK3
2
10K
LK3
1
10K
LK16-20
LK21-25
1
1
3
3
Figure 4-3. P144 I/O Board Terminations
4.1.1 Analogue Inputs (ANIN)
There are two fully floating A/D converters per I/O board, each
measuring five single-ended analogue input (ANIN) channels. Each
channel (ANIN 1-10) is configurable within a 0 to 5.25 volt or 0 to 22
mAmp input range. The board also provides two current-only inputs
(ANIN 11 and 12), for a total of 12 analogue inputs.
The primary measurement for ANIN 1-10 is voltage, which is
compared to a stable reference source. The channels are configurable
Revised Jan-07 I/O 4-3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson FloBoss S600 and is the answer not in the manual?

Emerson FloBoss S600 Specifications

General IconGeneral
BrandEmerson
ModelFloBoss S600
CategoryDesktop
LanguageEnglish

Related product manuals