Parameter Values
The tables below list the parameter value, or value range that are specific to the camera.
The configuration parameters are defined in the Multicam Configuration window,
Operation page, Hypermotion controller section.
On Vision Research cameras, two protocols can be used, each with a different port:
Values Port Protocol
Value set 1 RS422 ASCII
Value set 2 Ethernet TCP
The operational parameters are defined in the Hypermotion mode of the Remote Panel, in
the LCD secondary menu.
Operational Parameter Value Range Default Value
# Blocks 1 to 4 1
Pre-Roll from 00s00fr to 5s00fr 00s00fr
PGMSpeed 50, 100, 200, 300, 400,1000% 100
2nd Lever +/- 1000%, 0-1000% +/- 1000
Specific Behavior of Remote Panel Keys
• RECORD: Pressing this key while the current block is recording clears all memory
blocks and starts recording on the first one.
• RECORD: The Remote beeps if the CAM key refers to an empty block.
• TAKE: This key is operational in any mode.
• CLEAR: Press this key to delete the current memory block data.
Cue Points Management
• When a new ARM/REC command is issued on a block, all its cue points are cleared.
• If the Last Cue command cannot access the desired TC preroll, the player remains on
the current cue point.
• If the Last Cue command refers to a TC that does not exist anymore, the key beeps
but the OSD still displays the number of the cue that you wanted to go to.
224 9. Advanced Control Modes
EVS Broadcast Equipment SA Issue 12.05.A- May 2014