Checks to perform:
E62
E62: Heating timeout
E62
Thermal Limiter 2 open (Domestic GAS only and international electrical only)
WARNING
Check that all the connectors are correctly inserted
Clean the ventilation and repeat the Diagnostic Cycle to
check for any further alarms.
Check if Resistance between the terminals of heating
coil is 11 Ω ± 10%. (See Fig. 2)
NO
Replace the Heater and repeat the Diagnostic Cycle to
check for any further alarms.
Check Thermal limiter 2 (Inlet Thermal Limiter) for
continuity. Continuity is there?
Replace the Thermal Limiter 2 and repeat the Diagnostic
Cycle to check for any further alarms.
NO
Y
E
S
Replace the Electronic Control board and check for any
further alarms.
Y
E
S
Check if any foreign material restricting the passage of
air in Vent. (See Fig. 1)
NO
Y
E
S