184
E5D
E5D: Motor Control Board unknown message
E5D
Communication wiring , Motor control board, Main board, Software not
matching.
Checks to perform:
E5E
E5E: Motor control to Main Board communication incorrect
E5E
Wiring problem , Motor Control Board defective, Main Control Board defective,
User Interface Board defective.
Checks to perform:
WARNING
Check that all the connectors are correctly inserted.
WARNING
Check that all the connectors are correctly inserted.
Is the wiring between Main Control Board and Motor
Control Board proper? (Check for the continutity)
Replace / Repair the wiring and repeat the Diagnostic
Cycle to check for any further alarms.
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
Replace the Main Control Board and repeat the
Diagnostic Cycle to check for any further alarms.
Is the wiring between Main Control Board, Motor Control
Board and User Interface Board proper? (Check for the
continutity)
Replace / Repair the wiring and repeat the Diagnostic
Cycle to check for any further alarms.
Replace the User Interface Board and check for further
alarms. Is the appliance ok?
Appliance is ok
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
Replace the Main Control Board and repeat the
Diagnostic Cycle to check for any further alarms.
Y
E
S
Y
E
S
NO
NO
NO
NO
N
O
YES