NX-10 Expander Installation Guide
115
Programming the NX-534E listen-in module
Figure 14. NX-534E menu structure
You must enrol and default the NX-534E module before you begin to program the system. For more
information on enrolling and defaulting, see chapter 6. To program the NX-534E, select Installer
Menu>NX-534E Listen-in Module.
Configuring listen-in options
You can configure the listen-in mode and listen-in options. The following example prevents the
central station turning on the speaker at the premises if a duress, silent panic or hold-up alarm is
reported by the control panel.
1. Navigate with the ½¾ keys to NX-534E>Feature Select and press OK.
2. Scroll to Speaker Lockout>Yes and press OK.
3. The keypad beeps once to accept the change and returns to Speaker Lockout.
Programming timers
You can set timers to control various NX-534E listen-in module features. The following example sets
the line hold digit to 2 and line hold timeout to 60 seconds.
1. Navigate with the ½¾ keys to NX-534E>Line Hold Digit and press OK.
2. Select 2 and press OK.
Timers
Mode
Listen-in Only
Speaker Lockout
Mic A at Startup
Mic B at Startup
Answer Machine Defeat
Control Lvl 7&8
Feature Select
Light Control
Volumes
Model
Version
Reset Settings
Low Gain Listen In
High Gain Listen In
Speaker
Call Back Code
Line Hold Digit
Wrong PIN Digit Entries
Rings to Answer
Device 1
10.1
10.2
10.6
10.5
10.4
10.3
10.7
10.8
10.9
10.11
10.10
10.1.1
10.1.2
10.1.3
10.1.4
10.1.5
10.1.6
10.1.7
10.6.1
10.6.2
10.6.3
10.6.4
10.6.5
10.6.6
10.6.7
10.7.1
10.7.2
10.7.3
10.8.1
Line Hold Timeout
New Trip Hangup Time
Call Back Window Timer
Session Timeout
Indicator-A Time Remaining
Anti-Lock-Up Tone Time
Indicator-B Time Remaining
Module Number
House Code
10.8.1.
Devices 2 - 9
Same as above
10.8.1.