7 Any siren 28** Expander trouble 49♠ Auto disarm control
8 Zone bypass 29
Dynamic battery
test
50♠ Auto arm & disarm control
9 AC failure 30** Open schedule 51 Follow schedule of NX-508E
10 System low battery 31** Closed schedule 52
Flash X-10 for alarm
memory
11** Duress 32 Listen in 53 Flash X-10 for siren
12** Manual fire 33 Line seizure 54
Armed in ‘Exit’ mode, after
exit time
13** Manual medical alarm 34
Failed to
communicate
55 End listen-in
14** Keypad panic 35 Telephone line fault 56
Compare X-10 commands
with X-10 addresses
(activate exit by means of
DTMF commands)
15
Keypad tamper (wrong
codes)
36 Program mode 57 Disarmed : state of zone
Armed : latch
16** Automatic test 37 Download 58 Service required
17 Alarm memory 38
Follow zone status in
alarm
59 Armed in “STAY” mode
18 Entry 39
Over current (12
Vdc)
60 Sensor low battery
19 Exit 40 Box tamper 61 Sensor missing (lost)
20 Entry or exit 41 Siren tamper 62 B-alarm
*
See Schedule Times>Opening and Schedule Times>Closing/Autoarm
**
If set to follow condition, these events are one second
.
♠
Events 48, 49 and 50 arm or disarm the NX-10 at the open (disarm) or close (arm) time for the
appropriate schedule.
Note: For events 48 and 50, the keypad buzzer will sound one minute prior to auto arm if the zone value is 1.
If the zone value is 0, the keypad will not sound prior to auto arm.
Setting up schedules
You can set up a schedule to control the day and time at which the system automatically opens and
closes or the days on which specific output events are active. You can also specify certain days on
which the schedule is not active. For example, you might use a schedule to disarm the system each
morning at a certain time. However, on holidays you might not want the system to disarm at this
time. The following example sets up January 1st as the day on which schedule 1 is not active.
1. Navigate with the ½¾ keys to NX-507/508E>Output Exp 24>Schedules and press OK.
2. Scroll to Schedule 1>Active>Disable on Holidays>Yes and press OK.
3. Navigate with the ½¾ keys to Date of holidays>January>Day 1>1 and press OK.
4. The keypad beeps once to accept the change and returns to Day 1.
5. To use this schedule, enable Outputs>Schedules for the selected output. For information
on how to enable this option, see Configuring an output.