NX-10 Expander Installation Guide
83
Configuring an output
You can specify events, users and partitions that can activate a particular output. The output can be
controlled using a schedule or by an X-10 device. If an output is controlled by a schedule, it can be
activated during the times specified in the schedule only. If it is controlled by an X-10 device, it can
be activated during the time the X-10 device is switched on or off. The following example configures
output 1 on output expander 24 to be activated by a box tamper event. This output is controlled by
schedule 1.
1. Navigate with the ½¾ keys to NX-507/508E>Output Exp 24>Outputs and press OK.
2. Scroll to Output 1>Event>Tamper/Trouble>Box Tamper and press OK.
3. The keypad beeps once to accept the change and returns to Tamper/Trouble.
4. Scroll to Schedules and press OK.
5. Press the relevant keys to select schedule only and press OK.
6. The keypad beeps once to accept the change and returns to Schedules.
Configuring users
You can specify the user code that triggers the selected output. The following example sets user code
1 to activate outputs on output expander 24.
1. Navigate with the ½¾ keys to NX-507/508E>Output Exp 24>Outputs>Output 1 and
press OK.
2. Scroll to Event>Miscellaneous>Code Entry and press OK.
3. The keypad beeps once to accept the change and returns to Miscellaneous.
4. Scroll to Zone/User>(User) 1 and press OK.
5. The keypad beeps once to accept the change and returns to Zone/User.
6. Navigate with the ½¾ keys to Users>User 1>Outputs and press OK.
7. Press the relevant keys to select the outputs that the user code can activate and press OK.
8. The keypad beeps once to accept the change and returns to Outputs.