NX-10 Expander Installation Guide
77
Chapter 6 Setting up the NX-507E/NX-
508E
Overview
The NX-507E and NX-508E are output modules used to expand the output capabilities of the
NetworX control panel with the following functionality:
NX-507E SEVEN RELAY EXPANDER
Microprocessor controlled 7-relay module
Designed with 7 separate normally open and normally closed relay contacts for a
variety of applications, including access control, home control/automation, wireless
interfaces, and security functions.
Includes 1 low current open collector output (output 8).
NX-508E EIGHT OUTPUT EXPANDER
Microprocessor controlled 8-output module
Equipped with 8 low current open collector outputs.
Has a built-in parallel interface for local printouts of all communicator activity.
The NX-507E and NX-508E output expanders can be programmed to:
Activate for an event in any or all partitions, if the control panel supports partitions.
Set up each output to follow up to eight different schedules to either activate the
output during the On time, or to be used in conjunction with another programming
option to create time zones.