Business Continuity Manager Monitor stops. You can specify a suboperand to set the time at which
Business Continuity Manager Monitor must stop. If you omit a suboperand, Business Continuity
Manager Monitor stops after the cycle that is currently being processed finishes.
IMMEDIATE
Business Continuity Manager Monitor stops immediately after the action that is currently being
processed finishes. It does not wait until the cycle is finished.
label-name ~
<LABEL string up to 32 characters>
Business Continuity Manager Monitor stops after it finishes all the processes up to the
ACTION=STOPPOINT label name, which is specified in the YKMONCG file.
If the specified label name does not exist in the YKMONCG file, the request to stop Business Continuity
Manager Monitor is canceled.
Example
To stop a Business Continuity Manager Monitor instance whose identification name is YK, enter
the following command.
STOP YK
To stop the Business Continuity Manager Monitor instance whose identification name is YK at the
specified label STOPPOINT(LABEL1), enter the following command.
MODIFY YK,STOP LABEL1
Remarks
• If you use the STOP command in the operating system, it assumes that you specified the
following:
MODIFY
Δ1cataloged-procedure-for-startup-name[.identification-name]
,STOP
• Even when you enter the MODIFY STOP command that contains IMMEDIATE, if Business
Continuity Manager is processing the CLI command, it will not stop until the command finishes.
• If you enter a MODIFY STOP command after a MODIFY STOP command that contains
IMMEDIATE, the latter command is not executed.
• If you enter multiple MODIFY STOP or STOP commands, only the last command you entered
will be executed. However, if you enter a MODIFY STOP or STOP command after Business
Continuity Manager Monitor has already begun the stop process, that command is not
executed.
Forcibly stopping Business Continuity Manager Monitor
To forcibly stop Business Continuity Manager Monitor, use the CANCEL command. When you use
this command, all requests are canceled and Business Continuity Manager Monitor is instantly
stopped.
Format
If both the name of the cataloged procedure for startup and the identification name were specified
in the START command.
CANCEL
Δ1[cataloged-procedure-for-startup-name.]identification-name
If only the name of the cataloged procedure for startup was specified in the START command:
Starting and stopping the Business Continuity Manager Monitor 519