EasyManuals Logo
Home>HP>Software>XP P9500

HP XP P9500 User Manual

HP XP P9500
608 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #544 background imageLoading...
Page #544 background image
The BCM Monitor can also be used to share the same configuration file with other
users.
NOTE: If a configuration file is updated by another user, the Update Warning
panel is displayed when Business Continuity Manager users try to update the
configuration file from the ISPF panel, prompting them to choose whether to overwrite
the file.
Collecting audit logs
You can use the Business Continuity Manager agent to collect audit logs containing output
information concerning linkage with Replication Manager. To obtain audit logs, specify the
initialization parameter AUDITLOG. The resulting audit logs are output to SYSLOG.
Table 94 (page 544) indicates when an audit log is output and what messages could be output.
For details on the messages, see the HP P9000 for Business Continuity Manager Software Messages.
Table 94 When an audit log Is output
Output MessageOutput Timing
YKY001IThe Business Continuity Manager agent starts.
YKY051IThe Business Continuity Manager agent ends.
YKY300IA request for establishing a TCP connection is accepted.
YKY301IA TCP connection is properly released.
YKY304IThe format of the TCP connection request is wrong, or the
versions does not match.
YKY500IThe configuration file has been updated.
YKY680IA copy group is being operated on.
1
1
If the same CLI commands are executed multiple times during one API acceptance, only the result generated from the
last CLI command that was executed is output. If an error occurs and the CLI command execution is interrupted, the result
that was generated immediately before the interruption is output as an error.
The following example shows an audit log that is output by dissolving the copy pair from Replication
Manager and updating the configuration file.
YKY001I AGENT STARTED (06-60)
YKY300I 11:18:22 101,TCP CONNECTION ACCEPTED
YKY307I 11:18:25 101,TCP CONNECTION INFORMATION,REMOTE-HOST=10.209.148.53,REMO
YKY680I 11:18:25 201,YKDELETE,RC=0.
YKY301I 11:18:25 101,TCP CONNECTION ENDED NORMALLY
YKY300I 11:18:26 101,TCP CONNECTION ACCEPTED
YKY307I 11:18:26 101,TCP CONNECTION INFORMATION,REMOTE-HOST=10.209.148.53,REMO
YKY500I RESULT OF UPDATING THE CONFIGURATION FILE:SUCCESS
YKY301I 11:18:28 101,TCP CONNECTION ENDED NORMALLY
YKY051I AGENT ENDED NORMALLY
Starting and stopping Business Continuity Manager agents
This section describes the commands you can use to start, stop, and forcibly stop a Business
Continuity Manager agent.
For the symbols used in the explanation on the format of commands, see “Conventions in syntax
explanations” (page 591).
544 Linkage with Replication Manager

Table of Contents

Other manuals for HP XP P9500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP XP P9500 and is the answer not in the manual?

HP XP P9500 Specifications

General IconGeneral
BrandHP
ModelXP P9500
CategorySoftware
LanguageEnglish

Related product manuals