Used to specify the identification name that was specified in the START command when Business
Continuity Manager Monitor was started.
REPORT
Used to display the information for copy groups whose IDs are specified in the YKMONCG file.
The information to be displayed is specified by the following sub-operands:
CGID=copy-group-ID ~ <GROUP string up to 38 characters>
Used to specify the ID of the copy group for which you want to display the information. If the
specified copy group ID does not exist in the YKMONCG file, the REPORT request is canceled.
output-type ~ <<SUMMARY>>
Use the following options to specify the information to be displayed.
• SUMMARY
Number of copy pairs by copy pair status
• DETAIL
Details by copy pair
• STATS
Operational information for copy groups. This information can be displayed only when the
copy type is Continuous Access Asynchronous or Continuous Access Journal Z.
• RPO
Consistency information on copy groups. This information can be displayed only when the
copy type is Continuous Access Asynchronous or Continuous Access Journal.
message—level ~ <<STATUS>>
Specify the level of the message to be output. Specifiable values are CONS, ERROR, STATUS, and
INFO.
For details on message levels, see the HP P9000 for Business Continuity Manager Reference Guide
for the description on parameters in the YKMONOPT file.
If you only want to specify the message level and omit the output type, type ,, as shown in the
following example:
MODIFY YK,REPORT CGID=BCMCG,,CONS
Example
To display the operational information for the copy group (copy group ID: BCMTC) in the Business
Continuity Manager Monitor instance whose ID is YK, enter the following command:
MODIFY YK,REPORT CGID=BCMTC,STATS
SET command
To change the values specified in Business Continuity Manager Monitor parameter files after
Business Continuity Manager Monitor has started, use the MODIFY SET command. The following
values can be modified:
• CYCLETIME
• WAITTIMEOUT
• The monitoring status of a copy group
• MSGLEVEL
Operator commands available in BCM Monitor 523

Table of Contents

Other manuals for HP XP P9500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP XP P9500 and is the answer not in the manual?

HP XP P9500 Specifications

General IconGeneral
BrandHP
ModelXP P9500
CategorySoftware
LanguageEnglish

Related product manuals