Rev. 2.0
Maintenance Guide
6-2
6-2. Replacing the Ejector
1) Close the hand valve at the lower left portion of this main unit.
2) Disconnect the φ4 air tube c and φ6 air tube d.
3) Disconnect the cable e of the CAL VCUM SV assembly.
4) Remove the mounting screws f (2 pcs.) and replace the CAL VCUM SV assembly.
5) Reassemble the components in the reverse order of disassembly.
Closed
Opened
Shut down the air supply.
4
2
3
1
CAL VCUM SV
assembly