12-1. Replacing the Sensor and Adjusting the Height
1) In the KE-3010/3020V/3020VR, the sensors are arranged as shown in the Figure below.
If the sensor has been replaced, the height adjustment is needed.
Rear
Front
Reflector
ETF incorrect
insertion detection
Feeder float (ETF)
Feeder float
(Mechanical, outside)
Feeder float
(Mechanical, inside)
Feeder float
(Mechanical, inside)
Feeder float
(Mechanical, outside)
Feeder float (ETF)
40110007 Receiving
40110010 Emitting
Emitting 40093803
40110004 Emitting
40110003 Receiving
40110009 Receiving
40110000 Emitting
40110012 Emitting
Receiving 40110011
Emitting 40110006
Receiving 40110005
Emitting 40110002
Receiving 40110001
Emitting 40110008
ETF incorrect
insertion detection
Receiving 40110013
①
②
③
④
⑤
⑥
⑦
Figure 12-1-1