Rev. 2.0
Maintenance Guide
8-1
DANGER
To prevent any trouble caused by accidental machine start, always
shut-down the power before starting the maintenance and
adjustment work.
[8] VCS
8-1. Replacing the CCD Camera Lens
(Replace the CCD Camera and Lens as S-VCS Camera Assembly.)
1) Remove the nylatches of the light unit cover to detach the front and rear flat plate V.
2) Remove the cable clamp d on the rear to disconnect the power cable connector of the light
unit.
Additionally, if the machine is equipped with the optional VCS, disconnect the piping of the
change-over air cylinder, as well as the connector of the change-over sensor.
3) Remove the light unit set bolts c (4 locations) to detach the light unit.
Flat plate V
Nylatch
SL6051492TN
M5 × 12 SEMS cap bolts c × 4
Cable clamp d
Figure 8-1-1