9-10
9-12. Speed selection
You can select four transfer speeds, Fast, Middle, Slow1, and Slow2, for each component floor.
∗ Slow2 is effective only when the optional “slow 2 mode” is set.
Starting speed selection
Select “11. Speed Select” in the menu.
Press ↑ and ↓ buttons to select the floor number to change the speed. Press the ENTER
button and the transfer speed is displayed.
Fig. 9-12-1 Display of floor number selection
Fig. 9-12-2 Display of speed change
Change of transfer speed
Use → and ← buttons to select Fast, Middle, Slow1, or Slow2 (optional).
When you change the transfer speed and press the ENTER button, the floor number is
switched to the next one.
For changing the next one’s transfer speed, press the ENTER button to make the screen to
the speed change display and change the speed.
If you finish changing the speed, press the CANCEL button to save the change in EEPROM
and return to the menu selection screen.
Fig. 9-12-3 Writing in EEPROM
9-13. Teaching
Component data for test mode in MTC is used for the teaching in the test mode. The
component data selected in the menu “13. Input Cmpnt Count” is used here.
Starting teaching
Select “12. Teach In” in the menu.
The component number and name are displayed respectively on the upper and lower rows.
When you select the teaching, 3-point input is selected as default and the 3POINT button
illuminates.
Fig. 9-13-1 Selection of teaching floor
∗∗∗∗∗
・・・・
17-1
Fast → Slow