5) Crypto resync DSR pulse value: 0 (space/low/on)
6) Crypto resync CTS in-sync value: 1 (mark/high/off)
7) Crypto resync CTS pulse value: 0 (space/low/on)
7. Configure the cryptographic resynchronization options as described in
Table 47 on page 103
Table 47: Cryptographic Resynchronization Options
Field DescriptionField Name
Number of seconds to wait between loss of sync on the port and the first
resynchronization pulse.
Enter a value in the range 1 60. The default value is 4 seconds
Crypto resync wait time
Pulse width in seconds. This is the number of seconds the resynchronization pulse will
be asserted.
Enter a value in the range 1 -15. the default value is 1 second
Crypto resync pulse width
Number of seconds between the beginning of each pulse. This value minus the pulse
width equals the time between the end of one pulse and the beginning of the next pulse.
Enter a value in the range 1-1000. The default value is 8 seconds.
Crypto resync pulse period
State of DSR or DTR when the port is in sync.
Enter a value in the range 0-1. The default value is 1.
Crypto resync DSR in-sync value
State of DSR or DTR to be sent between the resynchronization pulses when the port is
out of sync.
Enter a value in the range 0-1. The default value is 0.
Crypto resync DSR pulse value
State of CTS or RTS when the port is in sync.
Enter a value in the range 0-1. The default value is 1.
Crypto resync CTS in-sync value
State for CTS or RTS to be sent between the resynchronization pulses when the port
is out of sync.
Enter a value in the range 0-1. The default value is 0.
Crypto resync CTS pulse value
Gathering Node Debugging Information (CTP Menu)
This topic describes how to enable gathering node debugging information on CTP devices.
To enable gathering node debugging information using the CTP Menu:
1. From the Main Menu, select 4) Node Diagnostics.
2. Select 10) Node debug data gathering.
103Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Configuring CTP Bundles

Table of Contents

Other manuals for Juniper CTP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper CTP Series and is the answer not in the manual?

Juniper CTP Series Specifications

General IconGeneral
BrandJuniper
ModelCTP Series
CategoryServer
LanguageEnglish

Related product manuals