Table 20: CTP Bundle Signaling Parameter Settings in the CTP Menu (continued)
Your ActionFunctionField
Select one:
•
0) Unused—Input signals are ignored.
•
1) Demand call.
If you chose Demand call, select an input signal value:
•
0=Space=Low=On—Signal is turned on.
•
1=Mark=High=Off—Signal is turned off.
Specifies the input signal depending on whether
the bundle is configured as the DCE or the DTE:
•
DCE—LL input signal.
•
DTE—DCD input signal.
LL (input)
or
DCD (input)
Enter a number from 0 through 3.Specifies the output signaling delay in packets.Output delay
(pkts)
Configuring Serial Port Parameters for CTP Bundles (CTPView)
This topic describes how to configure port parameters for serial interfaces.
Before you begin:
•
Log in to the CTPView software at least at the Net_Admin level.
•
Connect the CTPView server to the CTP device for which you want to configure bundles.
To configure serial port parameters for CTP bundles using CTPView:
1. In the side pane, select Bundle > Configuration.
2. Run your mouse over the Display and Select an Existing Bundle bar.
3. In the table of bundles, select the bundle that you want to modify.
4. Under Port Options configure the parameters as described in Table 21 on page 52.
5. Click Click to Submit Bundle AND Port Changes.
Table 21: CTP Bundle Serial Port Parameter Settings in CTPView
Your ActionFunctionField
Enter a description of up to 64
alphanumeric characters. Do not use the
following characters:
( ; ' " ) ]
Specifies a description for the port.Port Description
Copyright © 2018, Juniper Networks, Inc.52
Using Bundles to Create Logical Configurations for Physical Interfaces, CTP Release 7.3, CTPView Release 7.3