Table 24: Transparent Mode Parameter Settings in the CTP Menu (continued)
Your ActionFunctionField
Specify y (yes) or n (no).Specifies that the circuit uses the ST lead instead of the RTS and CTS
leads to sample local SD/TT/RTS/DTR signals and forward them to the
remote RD/RT/CTS/DSR signals.
The RTS and DTR leads are subject to additional delay and jitter because
they are signaling leads. On higher-speed circuits, the delay and jitter on
these paths make the signal choices nonoptimal. Therefore, you can
specify that the circuit uses the ST lead instead of the RTS and CTS leads,
which will not have this delay and jitter.
Use ST lead (instead of
RTS/CTS)?
Specify y (yes) or n (no).If you specify that the circuit uses the ST lead instead of the RTS and CTS
leads, you can specify whether the ST lead is an input lead.
Is ST an input?
Related
Documentation
Transparent Encoding Applications and Support Overview on page 12•
• How Basic Transparent Encoding Works on page 13
• Configuring Transparent Encoding for CTP Bundles (CTPView) on page 58
• Using Phase-Correction FIFO Buffer with Transparent Encoding on page 14
• Using Send Timing (ST) Clocking for Higher Speed Circuits with Transparent Encoding
on page 16
Configuring Bundle Pairs for TDM/TDC Operation (CTPView)
The TDM/TDC feature is supported on CTP2000 serial interfaces. TDM/TDC operation
requires both a low-speed bundle and a high-speed bundle. This topic describes how to
configure the high-speed and low-speed bundle port options when used for TDM/TDC
bundles using CTPView.
1.
Configuring the High-Speed CTP Bundle for TDM/TDC Operation
(CTPView) on page 62
2.
Configuring the Low-Speed CTP Bundle for TDM/TDC Operation (CTPView) on page 63
Configuring the High-Speed CTP Bundle for TDM/TDC Operation (CTPView)
Configure the high-speed bundle on an even-numbered port.
Before you begin:
•
Log in to the CTPView software at least at the Net_Admin level.
•
Connect the CTPView server to the CTP device for which you want to configure bundles.
To configure a high-speed CTP bundle for TDM/TDC operation using CTPView:
1. In the side pane, select Bundle > Configuration.
2. Run your mouse over the Display and Select an Existing Bundle bar.
Copyright © 2018, Juniper Networks, Inc.62
Using Bundles to Create Logical Configurations for Physical Interfaces, CTP Release 7.3, CTPView Release 7.3