Table 63: Serial Loop Parameter Settings in the CTP Menu
Your ActionFunctionField
Select one:
•
None—Removes the serial loop.
•
To NET—Creates a loop toward the network. Data arriving from the IP network
destined for the serial interface is looped back to the IP network and remote
customer device. The data is still transmitted from the IP network to the serial
interface, but data from the serial interface to the IP network and remote device
is blocked.
•
To I/F—Creates a loop toward the customer device attached to the serial interface.
Data arriving from the serial interface that is destined for the IP network is looped
back to the serial interface. The data is still transmitted from the serial interface
to the IP network, but data from the IP network to the serial interface is blocked.
Specifies the direction of
the serial loop or removes
the serial loop.
Serial
Loop
Related
Documentation
Serial Loops for CTP Bundles Overview on page 157•
Configuring BERT Testing for CTP Bundles (CTPView)
BERTs do not run on bundles that use transparent encoding or on fractional T1/E1 bundles.
To configure BERTs with CTPView:
1. In the side pane, select Bundle > Diagnostics.
2. Click Bit Error Rate Tester.
3. Run your mouse over the MouseOver to Select a Port to Display bar.
A list of bundles configured on the CTP device appears.
4. In the table of bundles, select the bundle for which you want to configure BERTs.
5. Configure the BERT parameters as described in Table 64 on page 164.
163Copyright © 2018, Juniper Networks, Inc.
Chapter 7: Configuring Diagnostic Testing for CTP Bundles