Table 64: BERT Parameter Settings in CTPView
Your ActionFunctionField
Select one:
Disabled—Disables BERT transmission on this
bundle.
Tx to Net—BERT pattern is injected toward the
IP network. User data transmitted in the direction
of the IP network is replaced with the BERT
pattern.
Tx to I/F—BERT pattern is injected toward the
serial interface. User data transmitted in the
direction of the IP network is replaced with the
BERT pattern.
Specifies whether this bundle acts as the BERT
transmitter. If the bundle is the BERT transmitter,
specifies the direction in which it transmits test data.
BERT
Injection
Select one:
Disabled—Disables BERT reception on this
bundle.
Rx from Net—BERT pattern is received from the
network.
Rx from I/F—BERT pattern is received from the
interface.
Specifies whether this bundle acts as the BERT receiver.
If the bundle is the BERT receiver, specifies the direction
from which it receives test data.
The BERT receiver does not disrupt the existing data flow
in either direction.
BERT
Reception
Select one:
MARK
ALT
511
2047
2^15-1
2^20-1
2^23-1
2^29-1
2^31-1
2^4-1
Specifies the type of BERT pattern.
BERT patterns are compatible with the external BERT
equipment that you are using. All patterns except 2^31-1
are compatible with the Fireberd 6000.
When you set up a bidirectional end-to-end BERT, you
must configure the same pattern on both bundles.
Patterns
Select the number of seconds.Specifies the rate at which CTPView checks the status
of the BERT and updates the synchronization status and
counters.
Update Rate
Click the button to inject an error into the pattern.
The Error Cnt should increment by one.
The BERT transmitter injects an error into the pattern to
verify that an end-to-end BERT has been established.
Inject Error
Related
Documentation
BERT Testing for CTP Bundles Overview on page 158
Displaying BERT Status and Counters for CTP Bundles (CTPView) on page 167
Copyright © 2018, Juniper Networks, Inc.164
Using Bundles to Create Logical Configurations for Physical Interfaces, CTP Release 7.3, CTPView Release 7.3

Table of Contents

Other manuals for Juniper CTP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper CTP Series and is the answer not in the manual?

Juniper CTP Series Specifications

General IconGeneral
BrandJuniper
ModelCTP Series
CategoryServer
LanguageEnglish

Related product manuals