Table 34: CTP Bundle Multiservice IRIG-B Port Parameter Settings in the CTP Menu (continued)
Your ActionFunctionField
Enter a number from 0.00 through 7.85
volts peak-to-peak.
This setting applies only if you set the
direction of the port to Tx.
Specifies the high output level, which is
measured in peak-to-peak voltage. This
setting is based on a 50-ohm
termination.
Output High Level
Enter a number from 0.00 through 7.85
volts peak-to-peak.
This setting applies only if you set the
direction of the port to Tx.
Specifies the low output level, which is
measured in peak-to-peak voltage. This
setting is based on a 50-ohm
termination.
Output Low Level
See Also Serial Multiservice Interface Module Overview on page 5•
Configuring Multiservice TDC Mode Parameters for CTP Bundles (CTP Menu)
Before you begin:
•
Disable the bundle before you modify the bundle options.
To configure Multiservice TDC mode port parameters using the CTP Menu:
1. From the CTP Main Menu, select 1) Bundle Operations.
2. Select 1) CTP.
3. Select a bundle from the list.
If you select an active bundle, you are prompted to disable the bundle before
configuring it.
4. Select 3) Port Config.
5. Select 2) Interface.
6. Select 1) Typeand set the type to Optional Interface: MultiSvc.
7. Follow the onscreen instructions and configure the options as described in
Table 35 on page 84.