Table 76: Performance Probe Tests Configuration Fields (continued)
Your ActionFunctionField
Type a number from 0 through
60000000.
Sets the maximum allowable standard
deviation (in microseconds), if exceeded,
triggers a probe failure and generates a
system log message.
Standard Deviation
Type a number from 0 through
60000000.
Sets the one-way time (in
microseconds), from the switch to the
remote server, if exceeded, triggers a
probe failure and generates a system log
message.
Egress Time
Type a number from 0 through
60000000 (microseconds).
Sets the one-way time (in
microseconds), from the remote server
to the switch, if exceeded, triggers a
probe failure and generates a system log
message.
Ingress Time
Type a number from 0 through
60000000.
Sets the outbound-time jitter (in
microseconds), if exceeded triggers a
probe failure and generates a system log
message.
Jitter Egress Time
Type a number from 0 and 60000000.Sets the inbound-time jitter (in
microseconds), if exceeded, triggers a
probe failure and generates a system log
message.
Jitter Ingress Time
Type a number from 0 through
60000000.
Sets the maximum allowable standard
deviation of outbound times (in
microseconds), if exceeded, triggers a
probe failure and generates a system log
message.
Egress Standard Deviation
Type a number from 0 through
60000000.
Sets the maximum allowable standard
deviation of inbound times (in
microseconds), if exceeded, triggers a
probe failure and generates a system log
message.
Ingress Standard Deviation
Traps
•
To enable SNMP traps for this
condition, select the check box.
•
To disable SNMP traps, clear the check
box.
Generates SNMP traps when the
threshold for jitter in outbound time is
exceeded.
Egress Jitter Exceeded
•
To enable SNMP traps for this
condition, select the check box.
•
To disable SNMP traps, clear the check
box.
Generates SNMP traps when the
threshold for standard deviation in
outbound times is exceeded.
Egress Standard Deviation Exceeded
Copyright © 2017, Juniper Networks, Inc.156