Section 11: TSP command reference Series 3700A System Switch/Multimeter Reference Manual
11-342 3700AS-901-01 Rev. D/June 2018
Also see
ptp.utcoffset (on page 11-307)
schedule.disable()
This function disables all alarms.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Function
Yes
Usage
schedule.disable()
Details
This command sets the schedule.alarm[N].enable attribute to 0 (schedule.OFF) for each
schedule alarm N.
Also see
schedule.alarm[N].enable (on page 11-338)
script.anonymous
This is a reference to the anonymous script.
Type
TSP-Link accessible
Affected by
Where saved
Default value
Attribute (R)
No
See Details
See Details
Not applicable
Usage
scriptVar = script.anonymous
scriptVar
The name of the variable that references the script
Details
You can use the script.anonymous script like any other script. Also, you can save the anonymous
script as a user script by giving it a name.
This script is replaced by loading a script with the loadscript or loadandrunscript commands
when they are used without a name.
Example 1
script.anonymous.list()
Displays the content of the anonymous
script.
Example 2
print(script.anonymous.source)
Retrieves the source of the anonymous
script.

Table of Contents

Other manuals for Keithley 3700A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 3700A Series and is the answer not in the manual?

Keithley 3700A Series Specifications

General IconGeneral
BrandKeithley
Model3700A Series
CategoryMultimeter
LanguageEnglish

Related product manuals