Idencaon of the products
When the technical data of the dierent versions was listed, the product name was entered
because it is easier to read than the individual product code of the product. The product name
is also used for categorising the accessories. The assignment of product name and order code
can be found in the Order chapter.
The product name contains the power in kW, the mains voltage class 120 V, 230 V or 400 V
and the number of phases.
In the product name, the power informaon always refers to the "Heavy Duty" load character-
isc.
The 1/3-phase inverters are marked at the end with "-2".
"C" marks the "Cabinet" version = inverter for the installaon into the control cabinet.
In tables, the rst 9 digits of the corresponding product code are used to idenfy the prod-
ucts:
Product code
I 5 5 A E □□□ 1 □□□□
Product type Inverter I
Product family i500
5
Product i550
5
Product generaon Generaon 1
A
Mounng type Control cabinet mounng
E
Rated power [W]
(Examples)
0.25 kW
125
0.55 kW 155
2.2 KW 222
3.0 kW 230
15 kW 315
30 kW
330
Mains voltage and connecon
type
1/N/PE AC 120 V
A
1/N/PE AC 230/240 V B
3/PE AC 230/240 V
C
1/N/PE AC 230/240 V
3/PE AC 230/240 V
D
3/PE AC 400 V
3/PE 480 V AC
F
Motor connecons Single axis
1
Integrated funconal safety Without safety funcon
0
Basic Safety STO A
Enclosure IP20, coated
V
Interference suppression Without
0
Integrated RFI lter 1
Applicaon area Default seng of parameters: EU region (50-Hz systems)
0
Default seng of parameters: US region (60-Hz systems)
1
Design types Standard I/O without network
000S
Applicaon I/O without network
001S
Standard I/O with CANopen
002S
Standard I/O with Modbus RTU
003S
Standard I/O with PROFIBUS
004S
Standard I/O with POWERLINK
012S
Standard I/O with EtherCAT
00KS
Standard I/O with PROFINET
00LS
Standard I/O with EtherNet/IP
00MS
Standard I/O with Modbus TCP
00WS
Product informaon
Idencaon of the products
12

Table of Contents

Other manuals for Lenze i550 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i550 Series and is the answer not in the manual?

Lenze i550 Series Specifications

General IconGeneral
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Overload Capacity150% for 60 seconds
Control TypeVector control
Communication InterfacesCANopen, Modbus, Ethernet, PROFIBUS, PROFINET
SafetySTO (Safe Torque Off)
Frequency Range0 Hz
Cooling MethodAir cooling
Storage Temperature Range-25°C to +70°C
Input Voltage Range3-phase 380...480 V AC -15%/+10%