Safety instrucons
Disregarding the following basic safety measures and safety informaon may lead to severe
personal injury and damage to property!
Observe all specicaons of the corresponding documentaon supplied. This is the precondi-
on for safe and trouble-free operaon and for obtaining the product features specied.
Please observe the specic safety informaon in the other secons!
DANGER!
Electrical voltage
Possible consequences: Death or severe injuries
Any work on the inverter must only be carried out in the deenergised state.
Inverter up to 45 kW: Aer switching o the mains voltage, wait for at least 180 s before
you start working.
Inverter from 55 kW onwards: Aer switching o the mains voltage, wait for at least 600 s
before you start working.
Basic safety instrucons
Personnel
The product must only be used by qualied personnel. IEC 60364 or CENELEC HD 384 dene
the skills of these persons:
They are familiar with installing, mounng, commissioning, and operang the product.
They have the corresponding qualicaons for their work.
They know and can apply all regulaons for the prevenon of accidents, direcves, and
laws applicable at the place of use.
Process engineering
The procedural notes and circuit details described are only proposals. It is up to the user to
check whether they can be adapted to the parcular applicaons. Lenze does not take any
responsibility for the suitability of the procedures and circuit proposals described.
The procedural notes and circuit details described in this document are only proposals. It is up
to the user to check whether they can be adapted to the parcular applicaons. Lenze does
not take any responsibility for the suitability of the procedures and circuit proposals descri-
bed.
Informaon on project planning
Safety instrucons
Basic safety instrucons
33

Table of Contents

Other manuals for Lenze i550 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i550 Series and is the answer not in the manual?

Lenze i550 Series Specifications

General IconGeneral
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Overload Capacity150% for 60 seconds
Control TypeVector control
Communication InterfacesCANopen, Modbus, Ethernet, PROFIBUS, PROFINET
SafetySTO (Safe Torque Off)
Frequency Range0 Hz
Cooling MethodAir cooling
Storage Temperature Range-25°C to +70°C
Input Voltage Range3-phase 380...480 V AC -15%/+10%