EasyManuals Logo

Lenze i550 Series Project Planning Manual

Lenze i550 Series
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Informaon on project planning
Project planning process
Dimensioning
3 methods for dimensioning
Fast: Selecon of the inverter based on the motor data of a 4-pole asynchronous motor.
Detailed: In order to opmise the selecon of the inverter and all drive components, it is
worth to execute the detailed system dimensioning based on the physical requirements of the
applicaon. For this purpose, Lenze provides the «Drive Soluon Designer» (DSD) design pro-
gram.
Manual: The following chapter guides you step by step to the selecon of a drive system.
Workow of a conguraon process
Dene required input variable
Calculate range of adjustment and determine rated point
Determine motor based on the rated data
Dene correcon factors for the inverter
Determine inverter based on the rated data
Check motor/inverter combinaon
Determine brake resistance
Final conguraon
Dene required input variables
Operang mode S1 or S6
Max. load torque M
L,max
Nm
Max. load speed n
L,max
rpm
Min. load speed n
L,min
rpm
Site altude H m
Temperature in the control cabinet T
U
°C
Informaon on project planning
27

Table of Contents

Other manuals for Lenze i550 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i550 Series and is the answer not in the manual?

Lenze i550 Series Specifications

General IconGeneral
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Overload Capacity150% for 60 seconds
Control TypeVector control
Communication InterfacesCANopen, Modbus, Ethernet, PROFIBUS, PROFINET
SafetySTO (Safe Torque Off)
Frequency Range0 Hz
Cooling MethodAir cooling
Storage Temperature Range-25°C to +70°C
Input Voltage Range3-phase 380...480 V AC -15%/+10%