EasyManuals Logo

Lenze i550 Series Project Planning Manual

Lenze i550 Series
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #262 background imageLoading...
Page #262 background image
Enclosures
The degree of protecon indicates the suitability of a motor for specic ambient condions
with regard to humidity as well as the protecon against contact and the ingress of foreign
parcles. The degrees of protecon are classied by EN 60529.
The rst code number aer the code leers IP indicates the protecon against the ingress of
foreign parcles and dust.The second code number refers to the protecon against the ingress
of humidity.
Code number 1 Degree of protecon Code number 2 Degree of protecon
0 No protecon 0 No protecon
1 Protecon against the ingress of foreign parcles d >
50 mm. No protecon in case of deliberate access.
1 Protecon against vercally dripping water (dripping
water).
2 Protecon against medium-sized foreign parcles,
d > 12 mm, keeping away ngers or similar.
2 Protecon against diagonally falling water (dripping
water), 15 ° compared to normal service posion.
3 Protecon against small foreign parcles d > 2.5 mm.
Keeping away tools, wires or similar.
3 Protecon against spraying water, up to 60 ° to the ver-
cal
4 Protecon against granular foreign parcles, d > 1 mm,
keeping away tools, wire or similar.
4 Protecon against spraying water from all direcons.
5 Protecon against dust deposits (dust-protected), com-
plete protecon against contact.
5 Protecon against water jets from all direcons.
6 Protecon against the ingress of dust (dust-proof),
complete protecon against contact.
6 Protecon against choppy seas or heavy water jets
(ood protecon).
Glossary
Abbreviaon Meaning
AIE Acknowledge In Error
AIS Acknowledge In Stop
OFF state Signal status of the safety sensor when it triggers or responds
CCF Common Cause Error (also β-value)
EC_FS Error Class Fail Safe
EC_SS1 Error Class Stop 1
EC_SS2 Error Class Stop 2
EC_STO Error Class Stop 0
ON − status Signal status of the safety sensor in normal operaon
FIT Failure In Time, 1 FIT = 10-9 Error/h
FMEA Failure Mode and Eect Analysis
FSoE Safety over EtherCAT (Fail Safe over EtherCAT)
GSDML File with device-specic data for establishing PROFINET communicaon
HFT Hardware Failure Tolerance
Cat. Category in accordance with EN ISO 13849-1
OSSD Output Signal Switching Device, tested signal output
PELV Funconal extra-low voltage with safe isolaon (Protecve Extra Low Voltage)
PL Performance Level (in accordance with ISO 13849)
PM Plus−Minus − switched signal paths
PP Plus−Plus − switched signal paths
PS PROFIsafe
PWM Pulse width modulaon
SCS Safe crawling speed
SD−In Safe Digital Input
SD−Out Safe Digital Output
SELV Safety Extra Low Voltage
SFF Safe Failure Fracon
SIL Safety Integrity Level in accordance with IEC 61508
Appendix
Glossary
262

Table of Contents

Other manuals for Lenze i550 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze i550 Series and is the answer not in the manual?

Lenze i550 Series Specifications

General IconGeneral
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Overload Capacity150% for 60 seconds
Control TypeVector control
Communication InterfacesCANopen, Modbus, Ethernet, PROFIBUS, PROFINET
SafetySTO (Safe Torque Off)
Frequency Range0 Hz
Cooling MethodAir cooling
Storage Temperature Range-25°C to +70°C
Input Voltage Range3-phase 380...480 V AC -15%/+10%