Enclosures
The degree of protecon indicates the suitability of a motor for specic ambient condions
with regard to humidity as well as the protecon against contact and the ingress of foreign
parcles. The degrees of protecon are classied by EN 60529.
The rst code number aer the code leers IP indicates the protecon against the ingress of
foreign parcles and dust.The second code number refers to the protecon against the ingress
of humidity.
Code number 1 Degree of protecon Code number 2 Degree of protecon
0 No protecon 0 No protecon
1 Protecon against the ingress of foreign parcles d >
50 mm. No protecon in case of deliberate access.
1 Protecon against vercally dripping water (dripping
water).
2 Protecon against medium-sized foreign parcles,
d > 12 mm, keeping away ngers or similar.
2 Protecon against diagonally falling water (dripping
water), 15 ° compared to normal service posion.
3 Protecon against small foreign parcles d > 2.5 mm.
Keeping away tools, wires or similar.
3 Protecon against spraying water, up to 60 ° to the ver-
cal
4 Protecon against granular foreign parcles, d > 1 mm,
keeping away tools, wire or similar.
4 Protecon against spraying water from all direcons.
5 Protecon against dust deposits (dust-protected), com-
plete protecon against contact.
5 Protecon against water jets from all direcons.
6 Protecon against the ingress of dust (dust-proof),
complete protecon against contact.
6 Protecon against choppy seas or heavy water jets
(ood protecon).
Glossary
Abbreviaon Meaning
AIE Acknowledge In Error
AIS Acknowledge In Stop
OFF state Signal status of the safety sensor when it triggers or responds
CCF Common Cause Error (also β-value)
EC_FS Error Class Fail Safe
EC_SS1 Error Class Stop 1
EC_SS2 Error Class Stop 2
EC_STO Error Class Stop 0
ON − status Signal status of the safety sensor in normal operaon
FIT Failure In Time, 1 FIT = 10-9 Error/h
FMEA Failure Mode and Eect Analysis
FSoE Safety over EtherCAT (Fail Safe over EtherCAT)
GSDML File with device-specic data for establishing PROFINET communicaon
HFT Hardware Failure Tolerance
Cat. Category in accordance with EN ISO 13849-1
OSSD Output Signal Switching Device, tested signal output
PELV Funconal extra-low voltage with safe isolaon (Protecve Extra Low Voltage)
PL Performance Level (in accordance with ISO 13849)
PM Plus−Minus − switched signal paths
PP Plus−Plus − switched signal paths
PS PROFIsafe
PWM Pulse width modulaon
SCS Safe crawling speed
SD−In Safe Digital Input
SD−Out Safe Digital Output
SELV Safety Extra Low Voltage
SFF Safe Failure Fracon
SIL Safety Integrity Level in accordance with IEC 61508