8400 BaseLine D | Software Manual
Parameter reference
Structure of the parameter descriptions
172 L Firmware 03.00 - DMS EN 5.0 - 07/2009
. 10.1.3.4 Parameters with subcodes
Description structure
Parameter setting in the »Engineer«
The »Engineer« parameter list displays each subcode individually. They are parameterised
as described in the previous chapters.
10.1.4 Parameter attributes
The table footers contain the parameter attributes:
Parameter | Name:
Cxxxxx | _____________
Data type: _______
Index: _______
Description
Setting range
(min. value | unit | max. value)
Subcodes Lenze setting
Cxxxxx/1
Cxxxxx/2
Cxxxxx/3
Cxxxxx/4
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Attribute Meaning
; Read access Read access to parameter possible.
; Write access Write access to parameter possible.
• Please also observe the following attributes:
; CINH Parameter value can only be changed when the controller is inhibit-
ed.
; PLC STOP Parameter value can only be changed when the application is
stopped.
; No transfer Parameter is not transferred to controller when the command Download parameter set
is
executed.
; COM Communication-relevant parameter
• this parameter is relevant for parameter data transfer via the system bus (CAN)
; MOT Parameter of the motor control