8400 BaseLine D | Software Manual
Parameter reference
Parameter list
174 L Firmware 03.00 - DMS EN 5.0 - 07/2009
10.2 Parameter list
This chapter describes all parameters of the operating system in numerically ascending
order.
C00002
Note!
The parameter descriptions are based on the software version V03.00.00.
Parameter | Name:
C00002 | Controller commands
Data type: UNSIGNED_8
Index: 24573
d
= 5FFD
h
Note:
Before switching off the supply voltage after executing a device command, check the successful execution of the
device command by means of the status display in C00003
!
Drive control (DCTRL)
: Device commands
Selection list
0Off / ready
1On / start
2Working
4 Action cancelled
5No access
6 No access controller inhibit
Subcodes Lenze setting Info
C00002/1 0: Off / ready Load Lenze setting
• All parameters are reset to the Lenze setting.
• Only possible when controller is inhibited.
C00002/2 0: Off / ready Load parameter set 1
C00002/3 0: Off / ready Reserved
C00002/4 0: Off / ready Reserved
C00002/5 0: Off / ready Reserved
C00002/6 0: Off / ready Reserved
C00002/7 0: Off / ready Save parameter set 1
C00002/8 0: Off / ready Reserved
C00002/9 0: Off / ready Reserved
C00002/10 0: Off / ready Reserved
C00002/11 0: Off / ready Save all parameter sets
• All parameter sets are saved in the memory module
with mains failure protection.
C00002/12 0: Off / ready Reserved
C00002/13 0: Off / ready Reserved
C00002/14 0: Off / ready Reserved
C00002/15 0: Off / ready Reserved
C00002/16 1: On / start Enable controller
"1" ≡ Enable controller
"0" ≡ Inhibit controller