Firmware 03.00 - DMS EN 5.0 - 07/2009 L 41
8400 BaseLine D | Software Manual
Commissioning
Password protection
3.5.1 Entry of a password not available yet
This information is required if you want to create the password protection for e.g. a
controller in default status.
[3-9] Enter password and confirm it
[3-10] Save password with mains failure protection
8888
-0-
_
-1-
PASS
PASS
5s
0000
_
`
....
8888
PASS
`
_
C094 c007
00
Status
Password
Menu
Code Subcode
Action
Action Display INFO Graphics
Mains on 00 After the mains has been switched on, "00" is displayed [3-9]
↵ -0- Without password protection you have free access from here to all
parameters and menu levels
-1-
↵ C002
C094 Press until C094 appears
↵ 00 00 is blinking, i.e. entry is possible
<8888> Entry of a password from 01 .... 9999
↵ C094 Password confirmed
01
_
`
`
_
c...
C094 c007
C002 c001
00
Status
Password
Menu
Code Subcode
Action
Action Display INFO Graphics
C002 Scroll down until C002 has been reached [3-10]
↵ c001 Subcode level reached
C007
↵ 00 00 is blinking
"01" 01 Enter "1", confirm with ↵ , i.e. password is saved with failure
protection